The world's fastest speed:150,000rpm
The world's greatest RCF:1,050,00xg
himac centrifuge technologies have realized the above greatest performance and the guietest operating sound "45dBA
2 in its the most compact body *.
CS150NX takes only 90 seconds to reach the world' s fastest speed 150,000rpm by himac original vacuumed drive unit. Now you can separate and purify protein, lipoprotein, cell organelle, DND and RNA, also carbon nano tubes, more efficiently than ever.
* versus other similar ultracentrifuge in this class, as of Oct 2008
Features
The Most Compact Body
-
-
The most compact body * (590(W) x 582(D) x 408(H) mm) does not occupy laboratory table. CS150NX carries the world greatest performance and many attractive and useful functions in its the most compact body *. Rotor chamber is allocated in a front part of the body with smooth sliding door, so that it is easy for operators to place a rotor. Touch-sensitive LCD panel with wide view angle is placed at a position and an angle for easy operation.PWM (pulse width modulation) motor control has realized substantial reduction in acceleration and deceleration time.

Powerful Imbalance Protection
-
-
Samples need to be balanced within 5mm by visual check only. Non-contact imbalance sensor always monitors vibration of the rotor and drive shaft. In case of abnormal vibration, the sensor activates and stops operation immediately.

Easy Operation with Touch-Sensitive LCD
-
Samples need to be balanced within 5mm by visual check only.
Non-contact imbalance sensor always monitors vibration of the rotor and drive shaft. In case of abnormal vibration, the sensor activates and stops operation immediately.

Quiet Operating Sound "45dBA"
-
This unusually quiet operating sound was realized by newly develope rigid-cotrol drive system and sound absorbing structure design. It does not disturb your researching works in the laboratory.
Quick Start-Up
-
-
It takes just 8 seconds(minimum) to be ready for operation since power switch is turn on. Initial screen is displayed on the LCD panel during booting up the system.

Powerful Vacuum Pump
-
Reaching time to high-vacuum status is reduced to half by optimized control of the oil diffusion pump. (comparing with our previous model.)
Easy Timer Setting
-
himac original RTC (real-time control) function makes timer setting easy. What you need to do is simply set start time or finish time with running time. It is easier than conventional delay time setting timer.
Acurate Control of Net Run-Time
-
The timer starts when the set speed is atteined by himac original actual run timer function (PAT.). It helps to precisely control of the net run-time and obtain high-reproducibility separation. Of course, conventional run timer is selelctable.
USB Interface (compatible to GLP/GMP)
-
USB port is equipped as standard specificiation. Operating data can be output in CSV format. LAN port is also selectable. (option)
RCF Calculation and Display
-
CS150NX eliminates many troublesome and time-consuming manual calculation. Also, you can start operation by entering g value, instead of running speed.
Specifications
Specifications
| Model |
CS150NX |
| Maximum Speed (rpm) |
150,000 |
| Maximum RCF (x g) |
1,050,000 (S140AT rotor) |
| Speed Control Accuracy (rpm) |
+/-50 (5,000 - 150,000) |
| Maximum Tube Capacity |
30ml x 6 tubes (S50A rotor) |
Maximum Tube Capacity (Swing Rotor) |
7ml x 4 tubes (S50ST rotor) |
| Timer |
1 min. to 99 hrs. and 59 min. with HOLD function, with RTC function |
| Rotor Temp. Control Range |
0 - 40 degree C (1 degree increments) |
| Rotor Cooling Method |
Thermo-module cooling system (HCF free) |
| Rotor Setting Method |
Self - Locking System |
| Screen Display |
Colour LCD (touch-sensitive) |
| Operational Noise (dBA) |
45 (1m front) |
| Heat Radiation Rate (kw) |
0.7 |
| Drive Unit Warranty |
5 years |
| Dimensions (mm) |
590 (W) x 582 (D) x 408 (H) |
| Footprint (m2) |
0.50 (850 x 590) |
| Weight (kg) |
97 |
| Power Requirements |
AC220V, 230V, 240V +/-10% (50/60Hz) Single phase, 8A (Maximum) |
| Standard Accessories |
Tool box and tool set, Instruction manual |
| Standard |
IEC61010-2-020, EN61326, CE Marking qualified |
| Catalog |
|